← All Maps

Schneider Electric PowerLogic PM5111

Power Meter

Addressing: Modicon
Registers: 2138
Address Description FC Count Data Type Byte Order Access Units Scale Range Category Vendor Notes
30 Meter Name 20 UTF8 — R/W — — — Config —
50 Meter Model 20 UTF8 — R/W — — — — —
70 Manufacturer 20 UTF8 — R/W — — — — —
90 Product ID Number 1 INT16U — R/W — — — — —
91 Hardware Detected 4 BITMAP — R/O — — 0x0000 – 0xFFFF — Bitmap indicating base hardware options detected Bit 01 = HMI Bit 02 = Modbus Serial Communications Port Bit 03 = Modbus Ethernet Communications Port Bit 04 = Digital Inputs Bit 05 = Digital Outputs Bit 06-16 Not Used
95 Supported Features 4 BITMAP — R/O — — 0x0000 – 0xFFFF — Bitmap indicating features supported Bit 01 = 1 Cycle Metering Bit 02 = 5/6 Cycle Metering Bit 03 = 50/60 Cycle Metering Bit 04 = Min/Max Bit 05 = Accumulated Energy Bit 06 = Conditional Energy Bit 07 = Time-of-Use Energy Bit 08 = Multi-tarrif Energy Bit 09 = Input Metering Bit 10 = Demand Bit 11 = Alarms Bit 12 = Waveform Capture Bit 13 = Datalogging Bit 14 = Not Used Bit 15 = Not Used Bit 16 = Not Used
129 Manufacturing Unit Id 1 INT16U — R/O — — — — Manufacturing Unit ID
130 Serial Number 2 INT32U — R/O — — — Config —
132 Date of Manufacture 4 DATETIME — R/O — — — — —
136 Hardware Revision 5 UTF8 — R/O — — — — —
141 Production History 01 1 INT16U — R/O — — — — —
142 Production History 02 1 INT16U — R/O — — — — —
143 Production History 03 1 INT16U — R/O — — — — —
144 Production History 04 1 INT16U — R/O — — — — —
145 Production History 05 1 INT16U — R/O — — — — —
146 Production History 06 1 INT16U — R/O — — — — —
147 Production History 07 1 INT16U — R/O — — — — —
148 Production History 08 1 INT16U — R/O — — — — —
149 Production History 09 1 INT16U — R/O — — — — —
150 Production History 10 1 INT16U — R/O — — — — —
151 Production History 11 1 INT16U — R/O — — — — —
152 Production History 12 1 INT16U — R/O — — — — —
153 Production History 13 1 INT16U — R/O — — — — —
154 Production History 14 1 INT16U — R/O — — — — —
155 Production History 15 1 INT16U — R/O — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —
00000 Register description hidden 03 1 UInt16 ABCD R — — — — —

2113 more registers available

Create a free account to view the complete register map.